FAN MOTOR / CAPACITOR
33.8100° S, 18.4700° EHeat Pump Fan Not Working in Table View
The fan is not turning, so the unit cannot absorb heat from the air and eventually locks out.
Diagnostic Breakdown
Symptoms, causes and what we do
Symptoms
What you are seeing
- Stationary fan while the unit runs
- Coil icing over
- Pressure faults after a short run
Likely Causes
What usually causes it
- Failed fan capacitor
- Burnt-out fan motor
- Obstruction or damaged blade
- Controller output failure
- Wiring or connector damage
Reyds Solution
What we check and repair
- Test the capacitor and motor windings
- Check controller output and wiring continuity
- Replace the motor or capacitor and balance the blade
- Clean the coil after any icing event
- Re-test pressures with airflow restored
Local Context
Why this happens in Table View
Modern family homes with pools and heavy salt-air exposure. Very high wind exposure and constant salt-laden air off Table Bay.
We see heat pump fan not working across domestic geyser retrofits, integrated hot water systems, pool plant and commercial installations. The diagnosis is the same discipline every time: prove the fault with readings before replacing anything.
Before you call
What to do right now
- 01Note the displayed water temperature, the set-point and any error code.
- 02Check the airflow path around the unit is clear and look for water beneath it.
- 03Note the brand, approximate age and when the problem started.
- 04Call 069 268 0988 so we can triage before attending.
Services
Heat pump services in Table View
Heat Pump Repairs Table ViewFAULT FINDING / COMPONENT REPAIRHeat Pump Installation Table ViewSIZING / PLUMBING / ELECTRICALHeat Pump Servicing Table ViewANNUAL SERVICE / PERFORMANCE CHECKHeat Pump Maintenance Table ViewPLANNED MAINTENANCE CONTRACTSEmergency Heat Pump Repairs Table ViewNO HOT WATER / PRIORITY ATTENDANCEHot Water Heat Pumps Table ViewDOMESTIC HOT WATER / 55°C SET-POINT
Other Faults
Other faults we diagnose in Table View
Heat Pump Making Noise Table ViewVIBRATION / BEARING NOISEHeat Pump Leaking Water Table ViewWATER INGRESS / CONDENSATEHeat Pump Tripping Electricity Table ViewBREAKER / EARTH LEAKAGE TRIPHeat Pump Losing Heat Table ViewHEAT LOSS / STANDING LOSSESHeat Pump Low Pressure Fault Table ViewLP LOCKOUTHeat Pump Refrigerant Leak Table ViewCIRCUIT LEAK / RECHARGE
Nearby Areas
Heat Pump Fan Not Working near Table View
FAQ
Heat Pump Fan Not Working — questions we are asked
Heat Pump Fan Not Working? Call 069 268 0988.
Tell us the brand, the error code and what changed. Diagnostic-led repairs on domestic, pool and commercial heat pump systems — from electrical faults and controller failures to refrigerant circuit and compressor problems.